Code: 0094
Display: XFER DETACH 2
Description: 2nd image transfer pressure / retraction failure
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS10 sensor check MFPB PJ16MFPB-8 (ON) C-4 7 CL5 operation check MFPB PJ10MFPB-5 (ON) C-6 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3 9 Change M3. 10 Change CL5. 11 Change MFPB.