Mã lỗi 0096 — Konica-Minolta Magicolor 4650EN

Code: 0096

Display: XFER DETACH 1
Description: 1st image transfer pressure / retraction failure
• The 1st image transfer retraction position sensor is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating. • The 1st image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS9 sensor check MFPB PJ7MFPB-11 (ON) J-5. 7 CL4 operation check MFPB PJ19MFPB-2 (REM) J-3 to 4. 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3. 9 Change M3. 10 Change CL4. 11 Change MFPB.