Code: 0096H
Description: 1st image transfer pressure/ retraction failure
• The Retraction Position Sensor/1st Image Transfer is not activated (retracted position) within a given period of time after the Intermediate Transport Motor has started rotating. • The Retraction Position Sensor/1st Image Transfer is not deactivated (pressed position) within a given period of time after the Intermediate Transport Motor has started rotating.
• The Retraction Position Sensor/1st Image Transfer is not activated (retracted position) within a given period of time after the Intermediate Transport Motor has started rotating. • The Retraction Position Sensor/1st Image Transfer is not deactivated (pressed position) within a given period of time after the Intermediate Transport Motor has started rotating.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC9 sensor check PWB-A PJ7A-13 (ON) 7-B-C. 7 CL4 operation check PWB-A PJ7A-10 (ON) 7-B. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.