Mã lỗi 0094H — Konica-Minolta Magicolor 5440DL

Code: 0094H

Description: 2nd image transfer pressure/ retraction failure
• The Retraction Position Sensor/2nd Image Transfer is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd Transfer Roller has been started. • The Retraction Position Sensor/2nd Image Transfer is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd Transfer Roller has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the PWB-A connector for proper connection and correct as necessary. 6 PC10 sensor check PWB-A PJ10A-6 (ON) 7-A. 7 CL5 operation check PWB-A PJ10A-8 (ON) 7-A. 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I. 9 Change PWB-A.