Code: 0521
Description: Abnormally high Fusing Pressure Roller temperature
• The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts. • The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the Heater temperature control starts.
• The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts. • The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the Heater temperature control starts.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-M. 5 Change PU1.