Code: 0018
Description: Color PC Drum Motor’s failure to turn
• The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is turning.
• The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is turning.
Remedy: 1 Check the connector of motor for proper connection and correct as necessary. 2 Check the connector of motor for proper drive coupling and correct as necessary. 3 Check the PWB-M connector for proper connection and correct as necessary. 4 M2 operation check PWB-M CNDM3-5 (REM) PWB-M CNDM3-8 (LOCK) C-23. 5 Change PWB-M.