Code: SC 686
Description: BCU-IPU communication error • After the machine is powered on or recovering from the power save mode, timeout occurs during BCU communication. • The break signal is received after the communication is normally established with the BCU. • Timeout occurs while the communication with the BCU is retried after a communication error.
Causes: • Board connector between BCU and controller loose • Board connector between controller and bridge board loose • Board connector between bridge board and IPU loose • BCU board defective • IPU board defective • Controller board defective • Bridge board defective
Remedy: 1. Turn the main switch off and on. 2. Check the cable connection between the board connector and BCU. 3. Check the cable connection between controller and bridge board. 4. Check the cable connection between bridge board and IPU. 5. Replace the BCU board. 6. Replace the IPU board. 7. Replace the controller board. 8. Replace the bridge board.