Description: IDU error • After the command is written into the DFID selfdiagnosis startup register, the correct value is not stored in the register in the specified duration. NOTE: This error is detected when the main switch is turned on. • After the negate interruption of FGATE occurs, IDU is not recognized in the specified duration. NOTE: This error is detected during scanning operations.
Causes: • IPU board defective (defective connection between ASIC and DFID, or Defective LSYNC)
Remedy: 1. Turn the main switch off and on. 2. Replace the IPU board.