Description: LD HP sensor not switched off (for K only) After the laser beam pitch was changed, it takes more than five seconds for the HP sensor to switch off.
Causes: • Defective motor • Defective sensor • Mechanical problem when switching the actuator • Brown fuse (FU81) on the Power supply unit
Remedy: 1. Turn the main switch off and on. 2. Check the sensor actuator position of the LD positioning motor. 3. Replace the LD positioning motor. 4. Replace the LD home position sensor. 5. Check and/or replace the PSU.