Code: SC 386
Description: Development gamma error K Any of the following conditions happens three consecutive times: . When the development gamma is out of the following range: 0.3 <Y> 6.0 . When Vk is out of the following range: -150V <Y>150V . Development gamma calculation error
Causes: • Unsuitable toner density • Toner supply mechanism problem • Laser exposure problem • Image transfer problem
Remedy: 1. Turn the main switch off and on . 2. Check the process control self-check result (SP3-975). If the result is not .1., fix the problem according to the table in section 4.1.2. 3. Print a full color image by disabling SC detection (SP5-809-001) and check if the image quality is OK. If the image quality is not OK, fix the problem. Then, enable the SC detection again.