Code: E003-0001
Description: Error in abnormally low temperature of fixing assembly
The status where the detected temperature of the sub thermistor is less than 100 deg C (approx. 0.38V equivalent) is detected 0.5 continuous sec or more after energization of the heater.
The status where the detected temperature of the sub thermistor is less than 100 deg C (approx. 0.38V equivalent) is detected 0.5 continuous sec or more after energization of the heater.
Causes: Error in sub thermistor, error in DC controller PCB.
Remedy: - Check of the connector of the low-voltage power supply PCB - Replacement of fixing sleeve unit - Replacement of DC controller PCB