Description: Error in primary transfer roller contact
Causes: Primary transfer roller contact mechanism does not normally function Cause: problem in contact mechanism / ITB tension sensor / pickup motor / DC controller PCB
Remedy: • Check contact mechanism • Check connectors of ITB tension sensor, pickup motor and DC controller PCB. • Replace ITB tension sensors • Replace pickup motors / DC controller PCBs