Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC302 — Ricoh Aficio Color 3006

Code: SC302

Description: Charge corona grid voltage error - Timing - When the charge corona unit grid is on during printing or process control - Condition - The feedback voltage is 4.8V or higher, or the PMW value is 50% or higher for 500 ms continuously.
Causes: • Charge corona unit not installed properly • Poor connection of cables • Defective high voltage supply board (C,G) • Defective I/O control board • Defective main control board.
Remedy: 1. Reinstall the charge corona unit properly or replace the charge corona unit. 2. Reconnect the connectors on the high voltage supply board (C,G), I/O control board, and main control board, or check the cables. 3. Check and clean the charge corona unit receptacle. 4. Replace the high voltage supply board (C,G). 5. Replace the I/O control board. 6. Replace the main control board. - Signals to Check - • Leak detection: CN201-1 or TP224 on I/O control board or TP162 on main control board Signals to Check - • Feedback signal: CN201-3 or TP226 on I/O control board or CN302-A4 or TP160 on main control board • PWM: CN201-4 or TP237 on I/O control board