Code: SC301
Description: Charge current leak - Timing - When the charge corona unit is on during printing or process control - Condition - The current leak was detected for 2 seconds.
Causes: • Charge corona unit not installed properly • Poor connection of cables • Defective high voltage supply board (C,G) • Defective I/O control board • Defective main control board.
Remedy: 1. Reinstall the charge corona unit properly or replace the charge corona unit. 2. Reconnect the connectors on the high voltage supply board (C,G), I/O control board, and main control board, or check the cables. 3. Check and clean the charge corona unit receptacle. 4. Replace the high voltage supply board (C,G). 5. Replace the I/O control board. 6. Replace the main control board. - Signals to Check - • Leak detection: CN201-1 or TP224 on I/O control board or TP162 on main control board