Code: SC326
Description: FGATE1 error - Timing & Condition - The main control board does not receive the FGATE signal from the LD control board during 3 revolutions of the transfer belt.
Causes: • Belt mark detection error • Electrical noise • Poor connection of connectors
Remedy: 1. Clean the belt mark located on the back side of the transfer belt or replace the belt if the belt mark is dirty or peeled off. 2. Clean the transfer belt home position sensor if it is dirty. 3. Clean the bias terminals of the development units if they are dirty. 4. Check if the cable connectors (CN606 & NC408) on the LD main control board and scanner IPU board are properly connected. 5. Check if the cable connectors (CN601 & CN306) on the LD main control board and main control board are properly connected. 6. Replace the LD main control board. 7. Replace the main control board. - Signals to Check - • FGATE: CN601-A2 or TP608 on LD main control board / CN306-A9 on main control board • Belt mark: CN218-B11, TP210, or CN233-A6 on I/O control board / CN303-B1, TP108, or CN306-B2 on main control board / CN601-B9 or TP606 on LD main control board If the machine is equipped with the controller, 1. Check if the connectors (CN609) on the LD control board and controller I/F board are properly set. 2. Check if the controller I/F board is properly connected. 3. Replace the interface board.