Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC557 — Ricoh Aficio Color 3506

Code: SC557

Description: Pressure roller temperature does not increase - Timing - Every 1 second, 2 minutes after the main switch turned on until the roller temperature reaches the ready condition - Condition - The pressure roller temperature does not increase by more than 3 °C for a minute during warm-up.
Causes: • Poor connection of connectors • Pressure roller fusing lamp brown • Pressure roller thermofuse opened • Defective main control board • Defective I/O control board
Remedy: 1. Check if the following connectors are properly connected: • Pressure roller fusing lamp connectors • CN303 on the main control board • CN206 and CN214 on the I/O control board 2. Replace the pressure roller fusing lamp if it is opened. 3. Replace the pressure roller thermofuse if it is opened. 4. Replace the main control board, I/O control board, or by checking the trigger signal at each pin. - Signals to Check - • Pressure roller fusing trigger: CN303-B7 on main control board / CN218-B5, or CN205-A5 on I/O control board.

← Xem tất cả mã lỗi Ricoh Aficio Color 3506