Mã lỗi SC558 — Ricoh Aficio Color 3506

Code: SC558

Description: Zero cross signal abnormal - Timing & Condition - Zero cross signals generated within a certain period do not reach a predetermined number.
Causes: • Poor connection of connectors • Blown fuse • Defective PSU • Defective main control board • Defective I/O control board
Remedy: 1. Check if the following connectors are properly connected; • CN205 and CN218 on the I/O control board • CN303 on the main control board • CN106 on the PSU 2. Check the continuity of the signal lines of the above cables. 3. Replace the PSU, I/O control board, or main control board by checking the signal line at each pin. - Signals to Check - • Zero cross: CN106-3 on PSU/ CN205-A6, TP250, or CN218-B8 on I/O control board / CN303-B4 or TP170 on main control board