Code: SC542
Description: Hot roller warm-up error - Timing & Condition - The hot roller thermistor does not output an analog value corresponding to the ready temperature within 12 minutes after the main switch is turned on.
Causes: • Poor connection of connectors • Hot roller fusing lamp blown • Hot roller thermofuse opened • Power fluctuation • Defective main control board • Defective I/O control board • Defective AC drive board
Remedy: 1. Check if the following connectors are properly connected: • Hot roller fusing lamp connectors • CN303 on the main control board • CN206 and CN214 on the I/O control board • CN105 on the PSU 2. Replace the hot roller fusing lamp if it is opened. 3. Replace the hot roller thermofuse if it is opened. 4. Check if the power supplied from the outlet fluctuates. 5. Replace the main control board, I/O control board, or PSU (check the trigger signal at each pin and replace any defective boards). - Signals to Check - • Hot roller fusing lamp trigger: CN303-B6 on main control board / CN205-A4, TP267, or CN218-B6 on I/O control board / CN106-5 on PSU.