Description: When the TT was connected, TT balance sensor L/R wasn't connected properly.
Remedy: 1 Connection failure of the TT balance sensor L/R harness. Reconnect the TT balance sensor L/R harness or relay connector harness. 2 TT balance sensor L/R attachment failure Reattach the TT balance sensor L/R. 3 LT/TT connector failure (machine side or TT side) Replace the LT/TT connector of the machine side or TT side. 4 TT balance sensor L/R failure Replace the TT balance sensor L/R. 5 TT control PCB failure Replace the TT control PCB ASSY. 6 Main PCB failure Replace the main PCB ASSY.