Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC360 — Ricoh Aficio Color 4106

Code: SC360

Description: Development bias error - Timing - When the development DC bias is on during printing or process control - Condition - The feedback voltage is 4.8V or higher, or the PWM value becomes 80% or higher for 500 ms continuously.
Causes: • Poor connection of connectors • Dirty terminals • Defective high voltage supply (B) • Defective I/O control board • Defective main control board
Remedy: 1. Clean the development roller shaft (terminal). 2. Clean the bias terminal if it is dirty. 3. Poor connection: Correct the leaf spring shape. 4. Replace the bias terminal if it does not move smoothly. 5. Check the connectors of high voltage supply cable and trigger lines are properly connected on the high voltage supply board (B), I/O control board, and main control board. 6. Replace the high voltage supply board (B) 7. Replace the I/O control board. 8. Replace the main control board. - Signals to Check - • Feedback signal: CN203-A12, TP228, or CN214-A5 on I/O control board / CN302-A5 or TP167 on main control board • PWM: CN203-A13 or TP234 on I/O control board