Mã lỗi SC500 — Ricoh Aficio Color 4106

Code: SC500

Description: Fusing motor error - Timing & Condition - • The feedback signal from the motor is still out of range 1 second after the trigger signal is sent. • The feedback signal becomes out of range for 2 seconds while the trigger signal is on.
Causes: • Poor connection of connector • Defective fusing motor • Defective I/O control board • Defective main control board
Remedy: 1. Check if the connector (CN204) is properly connected on the I/O control board. 2. Replace the fusing motor. (Output check: SP 5-804- 05,-06,-07,-08) 3. Replace the I/O control board. 4. Replace the main control board. 5. Check if anything causes overload for the fusing unit drive. - Signals to Check - • Motor OK: CN204-7 on I/O control board

← Xem tất cả mã lỗi Ricoh Aficio Color 4106