Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC541 — Ricoh Aficio Color 4106

Code: SC541

Description: Hot roller thermistor open - Timing - Every 1 second when the fusing unit is installed - Condition - The hot roller thermistor output is almost close to 5V, which corresponds to 0 °C, for 6 seconds continuously.
Causes: • Fusing unit not set properly • Poor connection of connector • Defective thermistor • Defective I/O control board • Defective main control board
Remedy: 1. Check if the fusing unit is properly set. 2. Check if the thermistor connector is properly connected. 3. Replace the thermistor if it is deformed. 4. Replace the thermistor if it is opened by measuring the resistance. (Refer to the Temperature/ Resistance Conversion Reference Table at the end of this table.) 5. Replace the I/O control board. 6. Replace the main control board. - Signals to Check - • Thermistor: CN206-B9, TP231, or CN214-B1 on I/O control board / CN302-B9 or TP154 on main control board.

← Xem tất cả mã lỗi Ricoh Aficio Color 4106