Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC400 — Ricoh Aficio Color 4506

Code: SC400

Description: Image transfer belt bias error - Timing - When the image transfer belt bias is on during printing or a process control self check - Condition - The feedback voltage is 4.8V or higher, or the PWM value is 50% or higher (indicating a leak) for 500 ms continuously.
Causes: • Poor connection of connectors • Defective high voltage supply board (T1,PCC) • Defective I/O control board • Defective main control board
Remedy: 1. Check if the connectors of high voltage cables and trigger lines are properly connected on the high voltage supply board, I/O control board, and main control board. 2. Clean the bias terminals. 3. Replace the high voltage supply board (T1,PCC). 4. Replace the I/O control board. 5. Replace the main control board. - Signals to Check - • Feedback signal: CN277-B3, TP221, or CN214-A4 on I/O control board / CN302-A6 or TP158 on main control board. • PWM: CN227-B4 or TP209 on I/O control board.

← Xem tất cả mã lỗi Ricoh Aficio Color 4506