Description: Pressure roller warm-up error - Definition - [A] Pressure roller temperature does not reach the ready temperature within 12 minutes after the main switch is turned on.
Causes: • Pressure roller thermistor not in position • Pressure roller lamp open • Pressure roller thermistor defective • Main control board defective