Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC551 — Ricoh Aficio Color 6010

Code: SC551

Description: Pressure roller thermistor open - Timing - at every 1 second after the fusing unit is set - Condition - The pressure roller thermistor output is almost close to 5V, which is correspond to 0°C, for 6 seconds continuously.
Causes: • Fusing unit not set properly • Poor connection of connector • Defective thermistor • Defective I/O control board • Defective main control board
Remedy: 1. Check if the fusing unit is properly set. 2. Check if the thermistor connector is properly connected. 3. Replace the thermistor if it is deformed. 4. Replace the thermistor if it is opened by measuring the resistance. (Refer to the attached Temperature/ Resistance Conversion Reference Table.) 5. Replace the I/O control board. 6. Replace the main control board. [ Signal Check ] • Thermistor: CN214-A9, TP232, or CN211-B2 on I/O control board / CN302-B8 or TP118 on main control board