Mã lỗi SC555 — Ricoh Aficio Color 6010

Code: SC555

Description: Pressure roller ready temperature abnormal - Timing - at every 1 second after the temperature reaches to the ready condition - Condition - The pressure roller thermistor output does not reach to the ready temperature within 7 minutes continuously.
Causes: • Fusing unit not set properly • Poor connection of connector • Defective thermistor • Defective I/O control board • Defective main control board • Defective AC drive board
Remedy: 1. Check if the fusing unit is properly set. 2. Check if the thermistor connector is properly connected. 3. Replace the thermistor if it is deformed. 4. Replace the thermistor if it is opened by measuring the resistance. (Refer to the attached Temperature/ Resistance Conversion Reference Table.) 5. Replace the main control board, I/O control board, or AC drive board by checking output from the thermistor and the trigger signal at each pin. [ Signal Check ] • Thermistor: CN214-A9, TP232, or CN211-B2 on I/O control board / CN302-B8 or TP118 on main control board. • Pressure roller fusing trigger: CN303-B7 on main control board / CN212-B5, TP240, or CN229-4 on I/O control board / CN7-7 on AC drive board.