Description: ADF communication error - Timing & Condition - After the main control board communicate successfully with the ARDF once, communication error is detected
Causes: • Poor connection of optical-fiber cable or damaged • Defective ARDF main board • Defective main control board
Remedy: 1. Check the connector of the optical-fiber cable is properly set on the ADF main board and main control board or check if it is damaged. 2. Replace the ARDF main board. 3. Replace the main control board.