Code: SC320
Description: Polygon motor error - Condition - • The polygon motor rotation speed stays out of the range 22 seconds after the main switch is turned on. • The polygon motor rotation speed becomes out of the range while the main switch is ON. (Polygon motor keeps rotating with constant speed while the main switch is ON.)
Causes: • Poor connection of connector • Defective polygon motor • Defective LD control board • Defective main scanner IPU board
Remedy: 1. Check the connector (CN602-5) on the LD control board is properly connected. 2. Check the continuity of harness. 3. Replace the polygon motor. 4. Replace the LD control board. 5. Replace the main scanner IPU board. [ Signal Check ] • Motor OK: CN602-2 on LD control board.