Code: SC350
Description: TD sensor communication error - Timing - When the main switch is turned on, during printing process, or process control self-check - Condition - The main control board cannot communicate with TD sensors
Causes: • Poor connection of connectors • Defective TD sensor interface board 1 and/or 2 • Defective I/O control board • Defective main control board
Remedy: 1. Check if the connectors on the TD sensor interface board 1 (copier) and the main control board (CN353) are properly connected. 2. Check if 5V and 38V are provided to the TD sensor interface board 1 from I/O control board (CN218). 3. Check if the harnesses are damaged. 4. Check if TD sensor interface board 1 and 2 are properly installed. 5. Replace TD sensor interface board 1, 2, main control board, and/or I/O control board.