Code: SC402
Description: Image transfer belt lubricant brush current leak - Timing & Condition - The current leak is detected more than 2 seconds.
Causes: • Defective high voltage supply board (Q1). • Defective I/O control board • Defective main control board
Remedy: 1. Check if the connectors on the terminal and high voltage supply board (Q1) are properly connected and if the harnesses are damaged. 2. Clean the receptacles. 3. Replace the high voltage supply board (Q1). 4. Replace the I/O control board. 5. Replace the main control board. [ Signal Check ] • Leak detection: CN215-B7 or TP137 on I/O control board