Code: SC440
Description: Drum motor error - Timing & Condition - • The feedback signal from the motor is still out of range 1 second after the trigger signal is sent. • The feedback signal becomes out of range for 2 seconds while the trigger signal is ON.
Causes: • Poor connection of connector • Defective drum motor • Defective I/O control board • Defective main control board
Remedy: 1. Check if the drum is locked by the cleaning blade. If yes, replace the cleaning blade. 2. Check if the connector (CN215) on the I/O control board is properly connected. 3. Check if the drum motor works properly in SP 5-804- 001 to 003. If not, replace the drum motor. 4. Replace the I/O control board. 5. Replace the main control board. [ Signal Check ] • Motor OK: CN215-A7 or TP135 on the I/O control board