Code: SC451
Description: Paper transfer belt motor lock - Timing & Condition - • The feedback signal from the motor is still out of range 1 second after the trigger signal is sent. • The feedback signal becomes out of range for 2 seconds while the trigger signal is ON.
Causes: • Defective motor • Defective motor dive board • Mechanical problem (drive transmission problem)
Remedy: 1. Check if the connectors on the paper transfer belt drive board and I/O control board (CN221) are properly connected. 2. Check if there is any mechanical problem by rotating the motor manually. 3. Replace the paper transfer belt motor. 4. Replace the paper transfer belt motor drive board. 5. Replace the I/O control board. 6. Replace the main control board. [ Signal Check ] • Feedback signal: CN221-B7 or TP154 on I/O control board