Code: SC496
Description: Humidity sensor - humidity detection error - Timing & Condition - The humidity sensor output for humidity is higher than 2V or less than 0.125V.
Causes: • Poor connection of connector • Defective humidity sensor • Defective I/O control board • Defective main control board
Remedy: 1. Check the connectors (CN210, 211 & CN302) are properly connected on the I/O control board and main control board. 2. Replace the humidity sensor. 3. Replace the I/O control board. 4. Replace the main control board. [ Signal Check ] • Humidity: CN201-4, TP236, or CN211-A8 on I/O control board / CN302-A2 or TP113 on main control board