Code: SC558
Description: Zero cross signal abnormal - Timing & Condition - Zero cross signals generated within certain period does not reach a predetermined number.
Causes: • Poor connection of connectors • Blown fuse • Defective AC drive board • Defective main control board • Defective I/O control board
Remedy: 1. Check if the following connectors are properly connected; • CN212 and CN229 on the I/O control board • CN303 on the main control board • CN7 on the AC drive board 2. Check the continuity of the signal lines of the above harnesses. 3. Replace the fuse (FU101) if it is blown. 4. Replace the AC drive boar, I/O control board, or main control board by checking the signal line at each pin. [ Signal Check ] • Zero cross: CN7-5 on AC drive board / CN229-6, TP216, or CN212-B8 on I/O control board / CN303-B4 or TP120 on main control board