Code: SC172
Description: Video processing error 3 - Timing - When the main switch is turned on (after auto gain control at scanner IPU board) - Condition - The white level corrected is outside the proper range.
Causes: • Poor connection of CCD harness • Dirty optics • Defective lamp regulator • Defective main scanner IPU board • Defective CCD
Remedy: 1. Check SP4-426-001 to 006 (RGB Gain). If their value is close to “255”, clean the optics section (exposure glass, white plate, mirrors, and lens). 2. Visually check that the exposure lamp turns on during warming-up after the main switch is turned on. If not, replace the lamp regulator. 3. Make sure the CCD flat cable is firmly connected at CN501 and CN404 on the CCD and scanner main IPU board. 4. Check the continuity of the flat cable. 5. Replace the main scanner IPU board. 6. Replace the CCD board and the lens unit.