Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC360 — Ricoh Aficio Color 6513

Code: SC360

Description: Development bias error - Timing - When the development DC bias turns ON during printing process or process control - Condition - The feedback voltage is 4.8V or higher, or PWM value becomes 80% or higher for 500 ms continuously.
Causes: • Poor connections • Dirty terminals • Defective high voltage supply (C/G/B) • Defective I/O control board • Defective main control board
Remedy: 1. Clean the development roller shaft (terminal). 2. Clean the bias terminal. 3. Replace the bias terminal if it does not move smoothly. 4. Make sure the connectors of high voltage supply cable and trigger lines are properly connected on the high voltage supply board (C/G/B), I/O control board, and main control board. 5. Replace the high voltage supply board (C/G/B) 6. Replace the I/O control board. 7. Replace the main control board. [Signal Check] • Feedback signal: CN217-2, TP171, or CN211-A5 on the I/O control board / CN302-A5 or TP111 on the main control board • PWM: CN217-3 or TP141 on the I/O control board

← Xem tất cả mã lỗi Ricoh Aficio Color 6513