Code: SC422
Description: - Timing & Condition - When the current leak is detected for 2 seconds, and the leak detection started 1 second after the PCC turned on. This leak signal is monitored twice a second. If it is detected twice in a row, this SC is displayed.
Causes: • PCC unit not properly installed • Broken corona wire • Defective high voltage supply board (T1/PCC/BR) • Defective I/O control board • Defective main control board
Remedy: 1. Make sure the PCC unit is properly installed. 2. If the discharge corona wire is broken, replace it. 3. Make sure the terminal and high voltage supply board (T1/PCC/BR) are properly connected and that the harnesses are not damaged. 4. Clean the contacts. 5. Replace the high voltage supply board (T1/PCC/BR). 6. Replace the I/O control board. 7. Replace the main control board. [Signal Check] • Leak detection: CN209-6 or TP275 on the I/O control board