Code: SC500
Description: Fusing motor error - Timing & Condition - • The feedback signal from the motor is still out of range 1 second after the trigger signal was sent. • The feedback signal goes out of range for 2 seconds while the trigger signal is ON.
Causes: • Poor connections • Defective fusing motor • Defective I/O control board • Defective main control board
Remedy: 1. Make sure that connector CN218 is properly connected to the I/O control board. 2. Replace the fusing motor. (Output check: SP 5-804-005) 3. Replace the I/O control board. 4. Replace the main control board. 5. Check for anything that might overload the fusing unit drive. [Signal Check] • Motor OK: CN218-7 or TP104 on the I/O control board