Code: SC504
Description: - Timing & Condition - • The upper limit sensor stays HIGH when the pick-up solenoid turns off. • The upper limit sensor stays LOW 1.5 seconds after the tray bottom plate begins to lower. • The upper limit sensor stays HIGH 10 seconds after the tray bottom plate starts to rise. • The upper limit sensor stays HIGH 3 seconds after the tray bottom plate starts to rise again
Causes: • Pick-up solenoid spring has come off • Defective upper limit sensor • Defective tray bottom plate • Defective tray lift motor • Defective I/O control board • Defective main control board
Remedy: 1. See if the spring of pick-up solenoid has come off. 2. Make sure the sensor harness is properly connected. 3. Clean the sensor, replace it if necessary (Input Check: SP5-803-014 to 017). 4. If the tray bottom lever is broken, replace it. 5. Pull out the paper tray and make sure the tray lift motor works properly (Output Check: SP5-804-75 to 82) 6. Replace the I/O control board. 7. Replace the main control board. [Signal Check] • Limit sensor H.P.: CN226-B8 or TP280 on the I/O control board