Code: SC522
Description: Duplex side fence jogger-- H.P. error - Timing & Condition - • The home position is still detected a few seconds after the side fence leaves the home position. • The home position is not detected 12 seconds after the side fence moves back into the home position.
Causes: • Duplex unit not installed properly • Excessive load • Poor connections • Defective side fence motor • Defective I/O control board
Remedy: 1. Pull out and re-insert the duplex unit. 2. Check that connector CN488 is properly connected to the duplex control board. 3. Check for anything that might cause the motor to overload. 4. Replace the side fence motor (Output Check: SP5-804 093 and 094). 5. Replace the I/O control board. [Signal Check] • Duplex Side Fence H.P.: CN207-B6 or TP293 on the I/O control board