Code: SC542
Description: Hot roller warmup error - Timing & Condition - The hot roller thermistor does not register the ready temperature within 12 minutes of the main switch being turned on.
Causes: • Poor connections • Blown hot roller fusing lamp • Opened hot roller thermofuse • Power fluctuations • Defective main control board • Defective I/O control board • Defective AC drive board
Remedy: 1. Make sure the following are properly connected: • Hot roller fusing lamp • CN303 on the main control board • CN212 and CN229 on the I/O control board • CN7 on the AC drive board 2. Replace the hot roller fusing lamp if it is blown. 3. Replace the hot roller thermofuse if it is opened. 4. Check for power fluctuations from the outlet. 5. Test the main control board, I/O control board, or AC drive board by checking the trigger signal at each pin. [Signal Check] • Hot roller fusing trigger: CN303-B6 on main control board/CN212-B6, TP248, or CN229-5 on the I/O control board/CN7-6 on the AC drive board.