Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC543 — Ricoh Aficio Color 6513

Code: SC543

Description: Overheating hot roller fusing lamp - Timing - Checked once a second when the fusing lamp is installed. - Condition - The hot roller thermistor output is lower than 0.3V (220°C) for 3 seconds in a row.
Causes: • Fusing unit not installed properly • Poor connections • Defective thermistor • Defective I/O control board • Defective main control board • Defective AC drive board
Remedy: 1. Make sure the fusing unit is installed properly. 2. Make sure the thermistor is properly connected. 3. Replace the thermistor if it is deformed. 4. Measure the thermistor’s resistance. If it is open, replace it. (Refer to the attached Temperature/ Resistance Conversion Reference Table.) 5. Test the main control board, I/O control board, or AC drive board by checking output from the thermistor and the trigger signal at each pin. [Signal Check] • Thermistor: CN214-A4, TP234, or CN211- B1 on the I/O control board/CN302-B9 or TP117 on the main control board. • Hot roller fusing trigger: CN303-B6 on the main control board/CN212-B6, TP248, or CN229-5 on the I/O control board/CN7-6 on the AC drive board.