Code: SC547
Description: Hot roller temperature does not increase - Timing - Checked every second, starting two minutes after the main switch is turned on and ending when the hot roller reaches the ready temperature. - Condition - Over one minute, the fusing roller temperature does not increase by more than 3°C.
Causes: Poor connections • Blown hot roller fusing lamp • Opened hot roller thermofuse • Defective main control board • Defective I/O control board • Defective AC drive board
Remedy: 1. Make sure the following are connected properly: • Hot roller fusing lamp • CN303 on the main control board • CN212 and CN229 on the I/O control board • CN7 on the AC drive board 2. Replace the hot roller fusing lamp if it is blown. 3. Replace the hot roller thermofuse if it is opened. 4. Test the main control board, I/O control board, or AC drive board by checking the trigger signal at each pin. [Signal Check] • Hot roller fusing trigger: CN303-B6 on the main control board/CN212-B6, TP248, or CN229-5 on the I/O control board/CN7-6 on the AC drive board.