Code: SC553
Description: Overheating pressure roller - Timing - Checked every second when the fusing unit is installed. - Condition - The pressure roller thermistor output is lower than 0.3V (220°C) for 3 seconds in a row.
Causes: • Fusing unit not installed properly • Poor connections • Defective thermistor • Defective I/O control board • Defective main control board • Defective AC drive board
Remedy: 1. Make sure the fusing unit is properly installed. 2. Make sure the thermistor is properly connected. 3. Replace the thermistor if it is deformed. 4. Measure the resistance across the thermistor. If it is open, replace it. (Refer to the attached Temperature/Resistance Conversion Reference Table.) 5. Test the main control board, I/O control board, or AC drive board by checking the output from the thermistor and the trigger signal at each pin. [Signal Check] • Thermistor: CN214-A9, TP232, or CN211- B2 on the I/O control board/CN302-B8 or TP118 on the main control board. • Pressure roller fusing trigger: CN303-B7 on the main control board/CN212-B5, TP240, or CN229-4 on the I/O control board/CN7-7 on the AC drive board.