Mã lỗi SC555 — Ricoh Aficio Color 6513

Code: SC555

Description: Abnormal pressure roller ready temperature - Timing - Checked every second after the temperature reaches the ready condition - Condition - The pressure roller thermistor output does not reach the ready temperature within 7 minutes.
Causes: • Fusing unit not installed properly • Poor connections • Defective thermistor • Defective I/O control board • Defective main control board • Defective AC drive board
Remedy: 1. Make sure the fusing unit is properly installed. 2. Make sure the thermistor is properly connected. 3. Replace the thermistor if it is deformed. 4. Measure the resistance across the thermistor. If it is open, replace it. (Refer to the attached Temperature/Resistance Conversion Reference Table.) 5. Test the main control board, I/O control board, or AC drive board by checking the output from the thermistor and the trigger signal at each pin. [Signal Check] • Thermistor: CN214-A9, TP232, or CN211- B2 on the I/O control board/CN302-B8 or TP118 on the main control board. • Pressure roller fusing trigger: CN303-B7 on the main control board/CN212-B5, TP240, or CN229-4 on the I/O control board/CN7-7 on the AC drive board.