Code: SC557
Description: Pressure roller temperature does not increase - Timing - Checked every second, starting two minutes after the main switch is turned on and ending when the ready temperature is reached. - Condition - For one minute, the pressure roller temperature does not increase by more than 3°C
Causes: • Poor connections • Blown pressure roller fusing lamp • Opened pressure roller thermofuse • Defective main control board • Defective I/O control board • Defective AC drive board
Remedy: 1. Make sure the following are connected properly: 2. Pressure roller fusing lamp 3. CN303 on the main control board 4. CN212 and CN229 on the I/O control board 5. CN7 on the AC drive board 6. Replace the pressure roller fusing lamp if it is blown. 7. Replace the hot roller thermofuse if it is opened. 8. Test the main control board, I/O control board, or AC drive board by checking the trigger signal at each pin. [Signal Check] • Pressure roller fusing trigger: CN303-B7 on the main control board/CN212-B5, TP240, or CNCN229-4 on the I/O control board/ CN7-7 on the AC drive board.