Code: SC558
Description: Abnormal zero cross signal - Timing & Condition - Zero cross signals generated within certain period do not reach a predetermined target value.
Causes: • Poor connections • Blown fuse • Defective AC drive board • Defective main control board • Defective I/O control board
Remedy: 1. Make sure the following are connected properly: • CN212 and CN229 on the I/O control board • CN303 on the main control board • CN7 on the AC drive board 2. Check the current through the signal lines in the above harnesses. 3. Replace the fuse (FU101) if it is blown. 4. Test the AC drive board, I/O control board, or main control board by checking the signal line at each pin. [Signal Check] • Zero cross: CN7-5 on the AC drive board/ CN229-6, TP216, or CN212-B8 on the I/O control board/CN303-B4 or TP120 on the main control board