Description: Scanner IPU communication error - Timing & Condition - After the main control board communicates successfully with the scanner IPU board once, and a communication error is detected.
Causes: • Poor connections • Defective sub/main scanner IPU board • Defective main control board
Remedy: 1. Check that connectors CN355 and CN407 are properly connected on the sub control board and scanner IPU board. 2. Replace the sub and/or main scanner IPU board. 3. Replace the main control board.