Code: SC726
Description: Sorter: End release motor error - Timing & Condition - The bin end open or close sensor does not activate as expected. When this error detected twice, this SC code is displayed.
Causes: • Poor connections. • Defective bin end open or close sensor • Defective end release motor • Defective main board
Remedy: 1. Make sure the bin end open and close sensors and end release motor are properly connected. 2. Replace the bin end open or close sensor. (Input check: SP5-803-126/127) 3. Replace the end release motor. (Output check: SP5-804-125) 4. Replace the main board.