Code: 548
Description: Fusing-temperature range violation (too high)
During paper transport, fusing temperature moved above limit (200°C for plain paper, 210°C for thick paper) and remained above limit for 10 seconds.
During paper transport, fusing temperature moved above limit (200°C for plain paper, 210°C for thick paper) and remained above limit for 10 seconds.
Causes: • TRIAC short • Fan not running